Skip to main content
File #: 2023-11488   
Type: New Business Status: Agenda Ready
File created: 6/2/2023 Meeting Body Development Review Committee
On agenda: 6/5/2023 Final action:
Title: SADDLE OAK CLUB EXPANSION - Waiver Request to a Major Site Plan in Review 5610 SW 60TH ST Ocala Project #2022120009 #29897 Parcel #35369-027-00 Atwell, LLC LDC 2.12.8. - Current boundary and topographic survey CODE states current boundary and topographic survey (one-foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be accepted if pre-approved by the Marion County Land Surveyor. APPLICANT requests waiver as we have survey outside of the property boundary, but not 100 feet beyond the boundary. We are proposing the use of LiDAR data to fill in the missing topography to 100 feet beyond the property boundary. LDC 6.13.3.D(2) - Types of stormwater management facilities CODE states commercial lots or subdivisions. Retention/detention areas shall be designed wit...
Sponsors: Development Review Committee
Attachments: 1. 6.1 Saddle Oak Club Expansion - Waiver Request to Major Site Plan in Review - 29897_

 

SUBJECT:

Title

SADDLE OAK CLUB EXPANSION - Waiver Request to a Major Site Plan in Review

5610 SW 60TH ST   Ocala 

Project #2022120009     #29897     Parcel #35369-027-00

Atwell, LLC

 

LDC 2.12.8. - Current boundary and topographic survey

CODE states current boundary and topographic survey (one-foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be accepted if pre-approved by the Marion County Land Surveyor.

APPLICANT requests waiver as we have survey outside of the property boundary, but not 100 feet beyond the boundary. We are proposing the use of LiDAR data to fill in the missing topography to 100 feet beyond the property boundary.

 

LDC 6.13.3.D(2) - Types of stormwater management facilities

CODE states commercial lots or subdivisions. Retention/detention areas shall be designed with a minimum berm width of 5 feet stabilized at six percent grade maximum around the entire perimeter of the facility and side slopes.

APPLICANT requests waiver as there is an existing dry retention stormwater pond that we are proposing an expansion to. We are only proposing a modification to a small area of this pond and adding a 5-foot maintenance path to the existing pond would require a major reworking of the pond outside of the proposed disturbed area.

Body

 

end