Title: Prestige Home Centers Minor Site Plan - Waiver Request to Minor Site Plan in Review 4020 S Pine Ave Ocala Project #2024120060 #32632 Parcel #3111-014-000 Kimley-Horn and Associates, Inc. LDC 2.12.24 - Landscape Requirements, Buffering CODE states Show location and dimensions of required land use buffering. (Ord. No. 13-20, ? 2, 7-11-2013) APPLICANT waiver is requested for the modified Type C buffer as previously discussed and supported by staff. LDC 6.8.8 - Building Landscaping CODE states A. Landscape plantings shall be provided along the public view sides of all proposed structures to reduce the monotony of large blank walls, reduce heat gain and glare, and enhance the aesthetic appearance of the building. B.Landscape areas shall be provided adjacent to or within 25 feet from the building walls and shall extend along 60 percent of the total length of the wall, excluding those areas required for access to the building. C. Landscape areas shall be a minimum of five feet wi...
Sponsors: Board of County Commissioners
Attachments: 1. 6.8. Prestige Home Centers North - Waiver Request to a Minor Site Plan in Review - 32632-.pdf

 

SUBJECT:

Title

Prestige Home Centers Minor Site Plan - Waiver Request to Minor Site Plan in Review

4020 S Pine Ave   Ocala

Project #2024120060     #32632     Parcel #3111-014-000

Kimley-Horn and Associates, Inc.

 

LDC 2.12.24 - Landscape Requirements, Buffering

CODE states Show location and dimensions of required land use buffering. (Ord. No. 13-20, § 2, 7-11-2013)

APPLICANT waiver is requested for the modified Type C buffer as previously discussed and supported by staff.

 

LDC 6.8.8 - Building Landscaping

CODE states A. Landscape plantings shall be provided along the public view sides of all proposed structures to reduce the monotony of large blank walls, reduce heat gain and glare, and enhance the aesthetic appearance of the building. B.Landscape areas shall be provided adjacent to or within 25 feet from the building walls and shall extend along 60 percent of the total length of the wall, excluding those areas required for access to the building. C. Landscape areas shall be a minimum of five feet wide allowing for a minimum distance of two feet from the façade to the innermost plants. D. Large trees shall not be located within 20 feet of a building. Accent/ornamental trees shall be located sufficiently to allow for healthy growth and to minimize the need for pruning.

APPLICANT waiver is requested for the building and landscaping requirements for this existing site. he majority of the front of the building will include a wooden ramp for ADA access.  Shrubs/hedges are proposed in the buffer between building and public ROW.

 

LDC 6.9.2 - Irrigation Plan Requirements

CODE states C. An irrigation plan which includes the following items shall be submitted: (1) Signature and seal of the authorized design professional is required, excluding those plans prepared by the owner of an owner occupied single-family residence or owner occupied duplex; (2) Limits of areas to be irrigated; (3) Table or chart which includes all components used within the system: (a) Symbol legend (b) Type of component, including brand and model (c) Application rate of each emitter type (d) Precipitation rate of each emitter type (4) System performance table: (a) Design pressure (b) Operating pressures (c) GPM of each zone (5) Location of rain sensor and/or soil moisture sensor;(6)Location of controller; (7) Location of point-of-connection or well; (8) Location of backflow prevention device; (9) Location of all valves, mainlines, lateral lines, and emitters;(10)Construction details as applicable to the design;(11) Notes including installation instructions and County's contractor licensing requirements when a contractor is used;(12) Notes regarding the close out and completion requirements; and (13) Notes regarding maintenance, post-construction adjustments, and watering restriction.

APPLICANT A waiver is requested to provide the flexibility of a design build irrigation system for this project. Per discussion with this can be supported.