File #: 2024-17540   
Type: New Business Status: Agenda Ready
File created: 12/6/2024 Meeting Body Development Review Committee
On agenda: 12/9/2024 Final action:
Title: Your Space Self-Storage - Waiver Request to Major Site Plan in Review 7365 SW HWY 200 Ocala Project #2022110040 #30776 Parcel #35670-000-00 Larson Design Group LDC 6.13.8.B(7) - Stormwater conveyance criteria CODE states Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof drains, prior to connection to the overall stormwater system, are exempt from minimum diameter requirements. LDC 7.1.3.J(1)(a) - Construction specifications CODE states Drainage facilities. (1) Pipe size and materials. (a) Drainage pipes shall be a minimum of 15 inches for residential and commercial driveways and 18 inches in diameter for all other stormwater systems within a right-of-way or easement associated with the right-of-way. APPLICANT states roof drains prior to connec...
Attachments: 1. 6.5 Your Space Self-Storage - Waiver Request to Major Site Plan in Review - 30776_

 

SUBJECT:

Title

Your Space Self-Storage - Waiver Request to Major Site Plan in Review

7365 SW HWY 200    Ocala 

Project #2022110040     #30776     Parcel #35670-000-00    

Larson Design Group

 

LDC 6.13.8.B(7) - Stormwater conveyance criteria

CODE states Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof drains, prior to connection to the overall stormwater system, are exempt from minimum diameter requirements.

LDC 7.1.3.J(1)(a) - Construction specifications

CODE states Drainage facilities. (1) Pipe size and materials. (a) Drainage pipes shall be a minimum of 15 inches for residential and commercial driveways and 18 inches in diameter for all other stormwater systems within a right-of-way or easement associated with the right-of-way.

APPLICANT states roof drains prior to connection to the overall system are exempt from minimum size. Area drains shown (D-5 and D-6) are for landscape areas. These drains collect water within the grass areas and convey it to the stormwater pond. Stormwater calculations show the maximum flow of 0.88 cfs with a pipe capacity of 1.31 cfs (25year/24hour storm). Additional criteria below (second page).

 

 

The following item was reviewed and approved with conditions as a Deviation Request under the authority of the County Engineer. The reference here is due to the request being part of the waiver application. No motion from the Committee is necessary.

 

LDC 7.1.3.J(1)(b) - Construction specifications

CODE states the use of reinforced concrete pipe shall conform to FDOT Standard Specifications. Other pipe material may be allowed if on the FDOT Qualified Products List (QPL), and with the approval of the County Engineer. For projects that are to be maintained by the County, justification for use of material other than reinforced concrete pipe shall include, but not be limited to data and values of water levels, soil conditions, resistivity, pH, chlorides and sulfates. For County projects, a value engineering proposal shall be provided with the justifications for the use of other than reinforced concrete pipe.

APPLICANT states roof drain connection pipes and area drain connection pipes are shown as ADS HDPE pipes are proposed for both the roof drain connections and the area drain connections. ADS HDPE pipe is an approved FDOT product. A note on sheet C105 was added and states the following "All HDPE pipe to be ADS, per FDOT approved product list and installation. UV protection is required for pipe ends. Contractor to submit shop drawings to the EOR for approval by the county prior to construction."

Body

 

 

end