Title: Conley Family Holdings 484 - Waiver Request to Major Site Plan in Review Project #2024060073 #31719 Parcel #44617-005-00 Rogers Engineering This item is under the authority of the County Engineer. A deviation request was approved on 8/22/24 with the following condition: The driveway is approved as shown on the plans; however, a cross access easement lining up with the easement on the property to the east shall be provided. Additionally, if either parcel to the east or west redevelops as a commercial property, this driveway may be removed and connection to the other adjacent driveway made at the owner's expense. LDC 6.11.5.B(3) - Driveway Access CODE states driveway location and minimum spacing shall be consistent with traffic safety standards. If standards cannot be achieved, the County Engineer or his designee can review and approve on a case-by-case basis. APPLICANT requests waiver because the existing cross-access easement is not paved and is located on a church's ...
Attachments: 1. 6.7 Conley Family Holdings 484 - Waiver Request to Major Site Plan in Review - 31719_

 

SUBJECT:

Title

Conley Family Holdings 484 - Waiver Request to Major Site Plan in Review

Project #2024060073     #31719     Parcel #44617-005-00   

Rogers Engineering

 

This item is under the authority of the County Engineer. A deviation request was approved on 8/22/24 with the following condition:

 

The driveway is approved as shown on the plans; however, a cross access easement lining up with the easement on the property to the east shall be provided. Additionally, if either parcel to the east or west redevelops as a commercial property, this driveway may be removed and connection to the other adjacent driveway made at the owner’s expense.

 

LDC 6.11.5.B(3) - Driveway Access

 

CODE states driveway location and minimum spacing shall be consistent with traffic safety standards. If standards cannot be achieved, the County Engineer or his designee can review and approve on a case-by-case basis.

APPLICANT requests waiver because the existing cross-access easement is not paved and is located on a church's property. The project will have large trucks making deliveries on weekdays and box trucks making numerous trips, and the turning movements will be troublesome. The church does not want to share its driveway with this kind of business and cannot afford to pave the cross-access easement.

 

 

This item is under the authority of the County Engineer. A deviation request was disapproved on 8/22/24.

 

Applicant must provide a 24’ wide paved cross access easement lining up with the cross-access easement on the parcel to the east.

 

LDC 6.11.4.B(2) - Cross Access -

CODE states cross access shall be provided and constructed for all commercial, industrial, and multi-family residential development on arterial and collector roads unless it is determined by the County Engineer to not be practical or reasonable due to adjacent features, specific type of development, or the potential development of the adjacent property.

APPLICANT requests waiver because the properties on both sides of the project have their own driveways and do not need to use the project's driveway.

 

 

 

LDC 6.12.12.D - Sidewalks

CODE states at the discretion of the Development Review Committee, in lieu of construction along external streets, the developer may pay a sidewalk fee to the County in an amount necessary to complete construction. This amount shall be determined by the project engineer and approved by the County with payment required prior to final plan approval. The County may use these funds toward the construction of sidewalks throughout the County based on priorities established by the Board.

APPLICANT requests waiver because the client wishes to pay fee $5,338.00 in lieu of sidewalk construction.

 

LDC 6.13.8.B(7) - Minimum Pipe Size

CODE states Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof drains, prior to connection to the overall stormwater system, are exempt from minimum diameter requirements.

APPLICANT requests waiver to allow use of 15-inch RCP with supporting hydraulic calculations.

 

LDC 6.8.6.K(4) - Buffers

CODE states D-Type buffer shall consist of a 15-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 25 percent of the required buffer.

APPLICANT requests waiver to request use of five ft. high four board black fence in lieu of wall, as preferred by the horse farm owner opposite of the buffer.

 

LDC 6.8.6.K(4) - Buffers

CODE states D-Type buffer shall consist of a 15-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 25 percent of the required buffer.

APPLICANT requests waiver to use existing oak trees in the Type "D" buffer in lieu of planted trees.

 

LDC 6.8.8.B - Building Landscaping

CODE states landscape areas shall be provided adjacent to or within 25 feet from the building walls and shall extend along 60 percent of the total length of the wall, excluding those areas required for access to the building.

APPLICANT requests waiver to request reduction of nine feet to length of plantings. Owner to provide potted plants on covered porch.