Title: Headsprings, LLC - Major Site Plan - Plan Revisions in Review #32134 - Waiver Reaffirmations and Waiver to Major Site Plan Revisions in Review Parcel #24141-000-00 #WaiverPIR-000801-2026 Davis Dinkins Engineering, PA Reaffirmation of Waiver Requests that were heard at the following DRC Meetings 7/14/25, 8/19/25, 10/6/25 for the Plan Revisions currently under review as shown on the Development Review waiver application. As well as consideration for the current waiver request below. LDC 2.12.3, 4, 6 Title Block CODE states 3. Title block shall be shown on all sheets denoting type of application; project name, location, county, and state; and date of original and all revisions. 4. Front page of the plan shall minimally include: A. Type of application; B. Project name centered at top of page ;C. Name, address, phone number, and signature of the owner and applicant (these signatures are not required until the final submittal); D. Signed certification by the owner as follows: I hereby...
Sponsors: Board of County Commissioners
Attachments: 1. 6.15 Headsprings, LLC - Waiver Request to a Major Site Plan - 32134_.pdf

 

SUBJECT:

Title

Headsprings, LLC - Major Site Plan - Plan Revisions in Review #32134 - Waiver Reaffirmations and Waiver to Major Site Plan Revisions in Review

Parcel #24141-000-00      #WaiverPIR-000801-2026

Davis Dinkins Engineering, PA

 

Reaffirmation of Waiver Requests that were heard at the following DRC Meetings 7/14/25, 8/19/25, 10/6/25 for the Plan Revisions currently under review as shown on the Development Review waiver application. As well as consideration for the current waiver request below.

 

LDC 2.12.3, 4, 6 Title Block

CODE states 3. Title block shall be shown on all sheets denoting type of application; project name, location, county, and state; and date of original and all revisions. 4. Front page of the plan shall minimally include: A. Type of application; B. Project name centered at top of page ;C. Name, address, phone number, and signature of the owner and applicant (these signatures are not required until the final submittal); D. Signed certification by the owner as follows: I hereby certify that I, my successors, and assigns shall perpetually maintain the improvements as shown on this plan (this signature is not required until the final submittal); E. Name, address, and phone number of the licensed professional; F. Each licensed professional is responsible for information shown within their particular field of practice and shall sign and seal, as applicable, as follows: (1) Licensed Design Professional Certification: I hereby certify that these plans and calculations were completed in accordance with all applicable requirements of the Marion County Land Development Code (LDC), except as waived; (2) Surveyor and Mapper Certification: I hereby certify that the survey represented hereon is in accordance with all applicable requirements of the LDC and meets the minimum technical standards as set forth by the Florida Board of Professional Surveyors and Mappers; G. A key location or vicinity map, with north arrow, at a scale suitable to show the location of the development with reference to surrounding properties, streets, municipal boundaries, sections, range, and township; H. A portrait oriented minimal 3 inches × 5 inches space, located 2¾ inches from the right edge of paper and ¾ inches from the top edge of paper, shall remain blank to allow for a County approval stamp; I. Index of sheets; J. List of utility providers; K. List of approved waivers, their conditions, and the date of approval; L. Data block. The items below are required and shall be listed in order as shown. If an item does not apply, it shall be clearly indicated as not applicable. (1) Parcel identification number; (2) Land use designation; (3) List of Development Agreements including Marion County Official Record Book and Page ;(4) Zoning information: (a) Zoning classification. (b) List of approved variances, their conditions, and the date of approval. (c) Special Use Permit case number and resolution. (d) Zoning requirements including lot area, width, setbacks, and building height. (5) Overlay zones; (6) Gross site acreage of all initial and anticipated parcels, and if different, the acreage of the development area, to the nearest hundredth of an acre; (7) Existing and proposed uses; (8) Existing and proposed building height; (9) Listing of site coverage (in square footage, acreage and percentage): (a) Existing and proposed building coverage by intended use with gross floor area and leasable/interior area; (b) Existing and proposed gross impervious area ;(c )Proposed gross non-residential floor area ratio or residential density; (d) Existing and proposed natural open space, improved open space, open water, and wetlands; (e) Existing and proposed preserved natural areas; (10) Number of required and provided parking spaces; (11) Projected daily trip generation and a.m./p.m. peak hour traffic volume; and (12) Proposed miles of road, number of lots, blocks and tracts, as applicable. 6. Provide location of septic systems and wells for Department of Health review.

APPLICANT - a waiver to the LDC sections due to the title block on the major site plan includes information listed in the LDC. Sheets incorporated for reference, i.e. the survey and landscape plan, are prepared by consultants and utilize their own font size and style and numbering convention. The index of sheets accurately reflects what is included in the plans.