Title:
|
Greenway Estates - Waiver Request to Improvement Plan in Review
Project #2023040043 #31022 Parcel #36626-000-00
Radcliffe Engineering
LDC 6.13.7.B(2) - Geotechnical criteria
CODE states Number of tests. At least two tests shall be performed within the boundary of each proposed retention/detention area. For each half acre of pond bottom area and for each lineal retention/detention area of 250 feet, an additional test shall be conducted. The County Engineer or his designee, may require additional tests if the initial tests indicate the need for them.
APPLICANT requests waiver to use one soil boring for the small drainage basin 5.0. Soil boring locations were estimated early on in the project and drainage retention requirements were reduced during final design therefore placing the second boring outside of the DRA limits. Soils are well drained sands throughout the site and additional borings are expected to corroborate the same result.
|