Please note: this meeting's Action Summary have not been finalized yet. Actions taken on legislation and their results are not available.

Meeting Details

Meeting Name: Development Review Committee Agenda status: Final
Meeting date/time: 6/20/2022 9:00 AM Action Summary status: Draft  
Meeting location: Office of the County Engineer
Published agenda: Agenda Agenda Published Action Summary: Minutes Minutes Meeting Extra1: Not available  
Agenda packet: Agenda Packet Agenda Packet
Meeting video:  
Attachments:
File #Ver.Agenda #TypeTitleActionResultVideo
     MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING.   Not available
   1. ROLL CALL   Not available
   2. PLEDGE OF ALLEGIANCE   Not available
   3. ADOPT THE FOLLOWING MINUTES:   Not available
2022-7567 13.1.MinutesJune 13, 2022   Not available
   4. PUBLIC COMMENT   Not available
   5. CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL   Not available
2022-7527 15.1.ConsentAVONLEA PHASE 1 REPLAT OF LOT 19 - Final Plat Project #2019110005 #27845 RM Barrineau & Associates   Not available
2022-7528 15.2.ConsentLAKE BESSIOLA SUBDIVISION (HAMLET) - Preliminary Plat Project #2021050013 #27923 EDA Consultants   Not available
2022-7529 15.3.ConsentMARION OAKS UNIT 2 PORTION OF (AKA GLEN AIRE PHASE 1B) - Improvement Plan Project #2021030040 #26423 Burrell Engineering   Not available
2022-7552 15.4.Consent7-ELEVEN CONVENIENCE STORE @ SW 49TH AVE & SW 95TH ST - Major Site Plan Revision Project #2020040032 #27132 (Revision to #25522) Bohler Engineering Request of minor modification due to revision of utility design to include necessary oil-water separator and reclaim tanks. Revision to sheet C-501 Utility Plan only.   Not available
2022-7530 15.5.ConsentPET PARADISE RESORT - Conceptual Plan Project #2022050059 #28498 Upham, Inc.   Not available
2022-7550 15.6.ConsentSTARK ENTERPRISES MULTI-FAMILY - Conceptual Plan Project #2021030002 #26338 Osborn Engineering   Not available
2022-7551 15.7.ConsentWEST SHIRE VILLAGE PHASE II - Conceptual Plan Project #2021070084 #27125 Osborn Engineering   Not available
2022-7553 15.8.ConsentALDANA PROPERTY PID # 8001-0204-01 - Waiver Request to Wastewater Connection MARION OAKS SUBDIVISION UNIT 1 Project #1999001649 #28598 Parcel #8001-0195-08 Aldana Contracting LLC 6.14.2.B(2)(A)1 - Wastewater Connection for New Single Family Residential CODE states New Single Family Residential and Duplex Construction. Wastewater system. Single Family Residential. New single family residential in the Urban or Rural area shall connect to a central sewer system if a sewer line from a central sewer system with available capacity is within a connection distance of 400 feet and connection may be made to the existing sewer line using a gravity line or an on-site pumping station; or Applicant willing to install NRSS in lieu of this SFR connecting to the closet available pressurized sewer force main.   Not available
2022-7554 15.9.ConsentHOLLAND PROPERTY, ARTHUR - Waiver Request to a Major Site Plan BRADFORD FARMS BLK B LOT 2(PB 007 PG 193) 5178 SW 93RD LN OCALA Project #2022060041 #28630 Parcel #35701-002-02 Permit #2022051864 Arthur Brian Holland 2.21.1.A Major Site Plan CODE states a Major Site Plan shall be submitted for review and approval prior to issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any thresholds identified in the code. APPLICANT requests waiver to add a shed (240 square feet). The site will be 1,959 square feet over the allowed 7,000 square feet per Bradford Farms Subdivision.   Not available
   6. SCHEDULED ITEMS:   Not available
2022-7555 16.1.New BusinessLAUREL COMMONS - Waiver Request to Preliminary Plat in Review ROLLING HILLS PUD (PORTION OF) Project #2022010045 #27876 Parcel #35636-001-00 Mastroserio Engineering 2.19.4.C - FINAL PLAT, MSBU RECORDING CODE states No Final Plat shall be accepted for filing by the Clerk of the Circuit Court until it has been approved by the Board as indicated on the plat by the signatures of the Chair and Clerk, and a Municipal Service Benefit Unit (MSBU), Community Development District (CDD), or other special district for the purposes of maintaining the improvements for this plat has been established. APPLICANT requests waiver to allow recording of the MSBU no later than 90 days after recording of the final plat. 6.3.1.C(3) 6.11.5.D(4) - Driveway restrictions corner lots Code states no closer than the lesser of 1/2 the lot width or 50 ft from end of radius. APPLICANT requests waiver to allow for this distance to be reduced as shown on the provided sketch. This is a private road subdivision with low speed traffic. 6.12.9.k - SUBDIVISION ROADS AND RELATED INFRASTRUCTURE CODE   Not available
2022-7557 16.2.New BusinessLAUREL COMMONS (AKA ROLLING HILLS) PUD - Waiver Request to Improvement Plan in Review Project #2007050034 #28367 Parcel #35636-001-00 Mastroserio Engineering 2.19.4.C- FINAL PLAT, MSBU RECORDING CODE states No Final Plat shall be accepted for filing by the Clerk of the Circuit Court until it has been approved by the Board as indicated on the plat by the signatures of the Chair and Clerk, and a Municipal Service Benefit Unit (MSBU), Community Development District (CDD), or other special district for the purposes of maintaining the improvements for this plat has been established. APPLICANT requests waiver to allow recording of the MSBU no later than 90 days after recording of the final plat. 6.13.3.D(1) - DRA MAINTENANCE BERM WIDTH CODE states Residential subdivisions. Retention/detention areas shall have side slopes no steeper than 4:1 (horizontal: vertical) with a minimum berm width of 12 feet stabilized at six percent grade maximum around the entire perimeter of the facility. Side slopes steeper than 4:1 may be allowed with additional accommodations relate   Not available
2022-7558 16.3.New BusinessMCGINLEY LANDING - Waiver Request to Preliminary Plat in Review Project #2022030231 #28208 Parcel #41200-056-03 Tillman And Associates Engineering LLC 6.12.2 - Right-of-way width Code states right-of-way shall be platted or dedicated, meeting the minimum right-of-way width established in table 6.12-1, to provide for the necessary access and other needed infrastructure improvements supporting the proposed development. Right-of-way can be provided by easement if approved by DRC. Applicant requests waiver to allow 30 feet of pavement with 15 feet utility easement. 6.12.9. - Subdivision roads and related infrastructure. Code states centerline radii shall be designed to accommodate the minimum design speed of 30 mph for subdivision local and minor local roads, 40 mph for major local and collector roads, and 45 mph for arterial roads in accordance with FDOT and AASHTO standards. Applicant requests waiver to reduce design speeds to a minimum of 10mph. Proposed curves warranting this design speed will have proper signage per MUTCD   Not available
2022-7559 16.4.New BusinessMCGINLEY LANDING - Waiver Request to Improvement Plan in Review Project #2022030231 #28209 Parcel #41200-056-03 TILLMAN AND ASSOCIATES ENGINEERING LLC Tillman And Associates Engineering LLC 6.12.2 - Right-of-way width Code states right-of-way shall be platted or dedicated, meeting the minimum right-of-way width established in table 6.12-1, to provide for the necessary access and other needed infrastructure improvements supporting the proposed development. Right-of-way can be provided by easement if approved by DRC. Applicant requests waiver to allow 30 feet of pavement with 15 feet utility easement. 6.12.9. - Subdivision roads and related infrastructure. Code states centerline radii shall be designed to accommodate the minimum design speed of 30 mph for subdivision local and minor local roads, 40 mph for major local and collector roads, and 45 mph for arterial roads in accordance with FDOT and AASHTO standards. Applicant requests waiver to reduce design speeds to a minimum of 10mph. Proposed curves warranting this design speed will have proper signage per MUTCD   Not available
2022-7560 16.5.New BusinessGOLDEN OCALA WEC SOUTH COMMERCIAL EXTENDED STAY HOTEL - Waiver Request to Major Site Plan in Review 1350 NW 80TH AVE OCALA Project #2021070087 #27759 Parcel #21068-000-02, 21068-000-01, 21068-001-01, & 21068-001-02 Tillman & Associates Engineering 6.13.8.B(7)- Minimum Pipe Size CODE states Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof drains, prior to connection to the overall stormwater system, are exempt from minimum diameter requirements. APPLICANT requests waiver to use roof drain and yard drain piping 8", 10", 12", 15" and site drainage 15" RCP. 7.1.3.J(1)(b) - Drainage Facilities Pipe Material CODE states the use of reinforced concrete pipe shall conform to FDOT Standard Specifications. Other pipe material may be allowed if on the FDOT Qualified Products List (QPL), and with the approval of the County Engineer. For projects tha   Not available
2022-7561 16.6.New BusinessSAFE HARBOR RV & BOAT STORAGE PHASE 2 - Waiver Request to Major Site Plan in Review Project #2016040034 #27654 Parcel #46005-002-00 Davis Dinkins Engineering 6.7.4 - Shade Tree Requirements CODE states Shade trees are required for all developments excluding residential developments. APPLICANT requests waiver for landscape and buffering as proposed on submitted landscape plan. 6.13.8.B(7) - Minimum Pipe Size Diameter CODE states Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof drains, prior to connection to the overall stormwater system, are exempt from minimum diameter requirements. APPLICANT requests waiver of minimum pipe size because the hydraulic calculations are sufficient to meet code and system is privately maintained. 6.11.4.B - Cross Access Pavement (Parallel Access) CODE states Cross access is required to reduce the use of   Not available
2022-7562 16.7.New BusinessSPIRES 27 - Waiver Request to Master Plan in Review SPIRES APARTMENT COMPLEX Project #2022030292 #28400 Parcel #13683-000-00,21577-000-00,21577-001-00 CHW 6.11.5. - Driveway Access CODE states Driveways provide the physical transition between a site and the abutting roadway. Driveways should be located and designed to minimize impacts on traffic while providing safe entry and exit from the development served. The location and design of the connection must take into account characteristics of the roadway, the site, and the potential users. APPLICANT requests waiver because the proposed driveway location is central to the site's frontage along US27, maximizing the distance between adjacent driveways. A pre-application meeting with FDOT was conducted on Nov. 11, 2021, at which time FDOT stated the driveway location was acceptable. An email from FDOT stating their position on the driveway location is attached to this form. 6.5.4. - Submittal Requirements CODE states An EALS/EALS-ER shall be submitted to the Office of the County Engineer concurrent with a c   Not available
2022-7563 16.8.New BusinessSPRUCE CREEK CC SOUTH COMMERCIAL SUBDIVISION - Preliminary Plat Extension Request Project #2015100068 #17141 Kimley-Horn & Associates Darrin Taylor - Carlton Fields Applicant’s third request for an extension to a preliminary plat in accordance with Section 252.363(1)(a), Florida Statutes, and Executive Order 2022-56. This preliminary plat currently expires on June 17, 2023. The extension being exercised is six months and 60 days to February 15, 2024.   Not available
2022-7564 16.9.New BusinessBRITTON, AMY & TODD - Waiver Request to a Major Site Plan Project #2006030070 #28604 Parcel #04613-000-08 Wilson & Wilson PA 2.16.1.B(10)-Family Division. CODE states a parcel of record as of January 1, 1992 that is located in the Rural Land may be subdivided for use of immediate family members for their primary residences. Within the Farmland Preservation area, each new tract and the remaining parent tract must be at least three (3) acres in size. Within the Rural Land outside the Farmland Preservation area each new tract and the remaining parent tract must be at least one (1) acre in size. Applicant request this one-time division to a family member of a larger (26.26 acres) parent track, with requisite 40ft of frontage on SR315. Retaining easement for parent tract.   Not available
2022-7565 16.10.New BusinessSAWCHUK PROPERTY, AUSTIN - Waiver Request for Family Division Project #2022050186 #28582 Parcel #5010-004-000 Sharon Sawchuk 2.16.1.B(10) - Family Division CODE states a parcel of record as of January 1, 1992 that is located in the Rural Land may be subdivided for use of immediate family members for their primary residences. Within the Farmland Preservation area, each new tract and the remaining parent tract must be at least three (3) acres in size. Within the Rural Land outside the Farmland Preservation area each new tract and the remaining parent tract must be at least one (1) acre in size. Applicant requests waiver to deed 2 acres to mother with a 27 foot access off of SE 160th Avenue Rd.   Not available
   7. CONCEPTUAL REVIEW ITEMS:   Not available
   8. DISCUSSION ITEMS:   Not available
   9. OTHER ITEMS:   Not available
   10. ADJOURN:   Not available