| | | | MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING. | | |
Not available
|
|
| | 1. | | ROLL CALL | | |
Not available
|
|
| | 2. | | PLEDGE OF ALLEGIANCE | | |
Not available
|
|
| | 3. | | ADOPT THE FOLLOWING MINUTES: | | |
Not available
|
|
2023-11884
| 1 | 3.1. | Minutes | June 26, 2023 | | |
Not available
|
|
| | 4. | | PUBLIC COMMENT | | |
Not available
|
|
| | 5. | | CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL | | |
Not available
|
|
2023-11876
| 1 | 5.1. | Consent | CRS @ MARION OAKS - Major Site Plan
Project #2022100125 #29790
CHW | | |
Not available
|
|
2023-11877
| 1 | 5.2. | Consent | CRS FORT MCCOY - Major Site Plan
Project #2022070058 #29533
CHW | | |
Not available
|
|
2023-11878
| 1 | 5.3. | Consent | OAK HAMMOCK PRESERVE - Final Plat
Project #2007100022 #29639
JCH Consulting Group
An Improvement Agreement with Surety Bond was Board approved on 6/20/23. | | |
Not available
|
|
2023-11879
| 1 | 5.4. | Consent | POINTE GRAND OCALA SOUTH - Major Site Plan
Project #2002080018 #28702
Kimley-Horn & Associates | | |
Not available
|
|
2023-11886
| 1 | 5.5. | Consent | WILLIAM NEAR RESIDENCE - Waiver Request to Major Site Plan
Project #2023050129 #30255 Parcel #50142-000-03
Moorhead Engineering Company
LDC 2.21.1.A(1) - Major Site Plan
CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet.
APPLICANT requests waiver to major site plan as the proposed development of this single-family residence and its associated airplane hangar exceed the subdivision original design impervious coverage of 6500 square feet per lot. However, the attached drainage report demonstrates there is sufficient excess volume in the designated water retention area to accommodate the additional impervious area for this parcel. | | |
Not available
|
|
2023-11887
| 1 | 5.6. | Consent | GOLDEN OCALA - VENDOR VILLAGE - Waiver Request to Major Site Plan
Project #2023060031 #30304 Parcel #21068-001-01
Tillman & Associates Engineering
LDC 2.21.1.A(1) - Major Site Plan
CODE states a Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet.
APPLICANT requests waiver to allow temporary modular buildings to be permitted over existing approved impervious area. Also include future relocation elsewhere on project site provided structures are being placed over existing impervious area and building permits are obtained as needed. Please refer to plan provided for size and number of units. | | |
Not available
|
|
| | 6. | | SCHEDULED ITEMS: | | |
Not available
|
|
2023-11880
| 1 | 6.1. | New Business | OCALA SOUTH PUD FKA LONGREEN FARMS PUD - Rezoning to PUD with Concept Plan
Project #2021080034 #30132
Atwell LLC | | |
Not available
|
|
2023-11881
| 1 | 6.2. | New Business | MARION COUNTY FIRE STATION #11 - Waiver Request to Major Site Plan in Review
11655 NW Gainesville RD All Units Ocala
Project #2021100037 #29994 Parcel #07399-083-02
Davis Dinkins Engineering
LDC 6.13.8.B(7) - Stormwater conveyance criteria
CODE states Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof drains, prior to connection to the overall stormwater system, are exempt from minimum diameter requirements.
APPLICANT requests a waiver for the reduction of minimum storm pipe size below 18" subject to hydraulic calculations requested.
LDC 6.10.2.A - Karst Analysis
CODE states an application for any new development or expansion of existing development, located within a high recharge or karst sensitive area as designated by the appropriate water management district or Marion County maps, shall submit an analysis of site conditions in suf | | |
Not available
|
|
2023-11882
| 1 | 6.3. | New Business | GREENWAY ESTATES - Waiver Request to Preliminary Plat in Review
Project #2023040043 #29995 Parcel #36626-000-00
Radcliffe Engineering
LDC 6.12.9(K) - Subdivision roads and related infrastructure
CODE states centerline radii shall be designed to accommodate the minimum design speed of 30 mph for subdivision local and minor local roads, 40 mph for major local and collector roads, and 45 mph for arterial roads in accordance with FDOT and AASHTO Standards.
APPLICANT requests to allow 25mph curves with appropriate signage.
LDC 6.12.12(A, B & C) - Sidewalks
CODE states A. Sidewalks shall be provided in the Urban Area, Rural Activity Centers, and Specialized Commerce Districts along arterial, collector, and major local streets where these streets adjoin the project and minimally along one side of the internal streets. Sidewalks shall be constructed with all-weather surfaces and shall meet Americans with Disabilities Act, Florida Building Code, and FDOT Design Standards. B. Sidewalks outside the right-of-way and independent of the street system are encouraged as an a | | |
Not available
|
|
2023-11888
| 1 | 6.4. | New Business | FLORIDA GENERAL TRADING - Waiver Request to Major Site Plan in Review
Project #2022030049 #29548 Parcel #03316-045-00
MCA Consulting Engineering
LDC 6.11.4.B(1&2) - Access Management
CODE states Cross Access (Parallel Access). (1) Cross access is required to reduce the use of the public street system, provide for movement between adjacent and complementary land uses, limit access to Arterial and Collector roads, and minimize full median openings. Cross access shall be shown on the plans and shall be established through a public easement. (2) Cross access shall be provided and constructed for all commercial, industrial, and multi-family residential development on arterial and collector roads unless it is determined by the County Engineer to not be practical or reasonable due to adjacent features, specific type of development, or the potential development of the adjacent property.
APPLICANT requests exemption of the required Cross Access due to the property to the north is undeveloped and is zone A-1 (General Agriculture). The property to the south is a flag lot and ser | | |
Not available
|
|
2023-11889
| 1 | 6.5. | New Business | LAUREL COMMONS IMRPOVEMENT PLAN (Entire Subdivision Waiver) - Stand Alone Waiver Request
Project #2007050034 #30310 Parcel #35636-001-00
Mastroserio Engineering
Reconsideration - this item was previously heard on 6/26/23 with a motion to transmit to the Board. Requesting motion to approve waiver request for stormwater criteria as outlined.
LDC 6.13.4.D - Stormwater Quantity Criteria Recovery Analysis
CODE states all retention/detention areas shall recover the total volume required to meet the discharge volume limitations within 14 days following the design rainfall event.
APPLICANT is requesting a waiver to allow for maximum allowable impervious area per lot to be determined as the proposed building pad plus driveways, walkways, and any accessory uses (8'x10' patios). Storm water calculations have been revised with no safety factor applied and with the maximum impervious coverage for the subdivision. The revised analysis indicates that the ponds recover & meet county criteria. (see provided calculations)
Reconsideration - this item was previously heard on 6 | | |
Not available
|
|
2023-11890
| 1 | 6.6. | New Business | REINHARDT PROPERTY - Waiver Request to Major Site Plan
Project #2023060071 #30346 Parcel #49633-000-00
Tillman & Associates Engineering
LDC 2.21.1.A(1) - Major Site Plan
CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet.
APPLICANT requests waiver for a residential project on a 20.15-acre (A-1) property. Owner seeks to add 31,604 square feet impervious (3.6%) for home, garage, and driveway. Most of the site drains to an isolated natural low that could be enhanced to provide additional storage of stormwater runoff, if needed. Request approval to work with staff on mutual agreeable solutions for storm controls. | | |
Not available
|
|
2023-11891
| 1 | 6.7. | New Business | PIONEER RANCH PH 3&4 - Waiver Request to Preliminary Plat in Review
Project #2023040020 #29974 Parcel #35700-000-04
Tillman & Associates Engineering
LDC 6.4.3.A - Preliminary Plat Survey Requirement
CODE states current boundary survey of the project boundary including location of all interior improvements, not more than one year old, or as approved by the County Surveyor, and meeting requirements as set forth in Ch. 5J-17.52 FAC. If the Preliminary Plat is one phase of lands to be platted, a survey of the overall proposed site is acceptable.
APPLICANT requests a waiver to use current survey, as Mass Grading has been approved and construction is active on site. | | |
Not available
|
|
2023-11892
| 1 | 6.8. | New Business | TRANQUILITY SPRINGS RV RESORT - Waiver Request to Improvement Plan in Review
Central Florida RV Park @ CR 25
Project #2022030315 #28257 Parcel #39279-000-01,39279-026-00, & 39279-028-00
Tillman & Associates Engineering
LDC 2.18.4.C - Construction, completion, and close out
CODE states all subdivision improvements shall be constructed in accordance with approved plans and shall conform to regulations and specifications in effect on the date of approval of the improvement plans.
APPLICANT requests to commence site grading prior to improvement plan approval at the developer's risk. We would like to start utility installation once FDEP permits are obtained. | | |
Not available
|
|
2023-11893
| 1 | 6.9. | New Business | BURNS STORAGE BUILDING - Waiver Request to Major Site Plan
16796 SE 76TH Chatham AVE The Villages
Project #2023060044 #30318 Parcel #4836-004-000 Permit #2023042885
Woodys Enterprises
LDC 2.21.1.A - Major Site Plan
CODE states a major site plan shall be submitted for review and approval prior to the issuance of a building permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet.
APPLICANT requests a waiver to the major site plan for a storage building. The site will be over the allowed 10% (22,129 square feet) per the Chatham Acres subdivision drainage plan. | | |
Not available
|
|
2023-11894
| 1 | 6.10. | New Business | MARTIN LANDS - Plat Vacation
Project #2023060064 #30339
Parcel #12747-000-00 and 12747-004-00
Rogers Engineering
The applicant is requesting to vacate those certain portions of Lot 56, Lot 60 and Lot 61, Martin Lands, Plat Book A, Page 87 Public Records of Marion County, Florida. Vacating these portions will allow for an AG Lot Split to be performed. | | |
Not available
|
|
| | 7. | | CONCEPTUAL REVIEW ITEMS: | | |
Not available
|
|
2023-11895
| 1 | 7.1. | Committee Item | KLEERVIEW INVESTMENT GROUP - Conceptual Plan
Project #2023060025 #30294
Kleerview Investment Group | | |
Not available
|
|
| | 8. | | DISCUSSION ITEMS: | | |
Not available
|
|
| | 9. | | OTHER ITEMS: | | |
Not available
|
|
| | 10. | | ADJOURN: | | |
Not available
|