Please note: this meeting's Action Summary have not been finalized yet. Actions taken on legislation and their results are not available.

Meeting Details

Meeting Name: Development Review Committee Agenda status: Final
Meeting date/time: 1/29/2024 9:00 AM Action Summary status: Draft  
Meeting location: Office of the County Engineer
Published agenda: Agenda Agenda Published Action Summary: Minutes Minutes Meeting Extra1: Not available  
Agenda packet: Agenda Packet Agenda Packet
Meeting video:  
Attachments:
File #Ver.Agenda #TypeTitleActionResultVideo
     MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING.   Not available
   1. ROLL CALL   Not available
   2. PLEDGE OF ALLEGIANCE   Not available
   3. ADOPT THE FOLLOWING MINUTES:   Not available
2024-13979 13.1.MinutesJanuary 22, 2024   Not available
   4. PUBLIC COMMENT   Not available
   5. CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL   Not available
2024-13980 15.1.ConsentCRS @ Marion Oaks (Revision To 29790) - Major Site Plan Revision Project #2022100125 #30733 CHW   Not available
   6. SCHEDULED ITEMS:   Not available
2024-13981 16.1.New BusinessSW 100th Street Roadway Improvement - Waiver Request to Off-Site Improvement Plan in Review Project #2022070105 #30253 Parcel #35680-008001 & 35697-000-02 Radcliffe Engineering LDC 6.12.9.K - Subdivision roads and related infrastructure CODE states Centerline radii shall be designed to accommodate the minimum design speed of 30 mph for subdivision local and minor local roads, 40 mph for major local and collector roads, and 45 mph for arterial roads in accordance with FDOT and AASHTO Standards. APPLICANT requests waiver to allow 30 mph design speed with appropriate signage. Curves to be signed as required. Reduced design speed will match speeds at existing east and west extensions of SW 100th Street and fit within existing R/W along with County requested multi modal path. LDC 6.12.3.A - Typical sections CODE states All roadway improvements shall meet the minimum requirements given in the Table 6.12-2 and be in concurrence with the additional tables in this division. Typical sections are detailed cross section depictions of the highway's principal elements th   Not available
2024-13982 16.2.New BusinessSWC US HWY 301 & SE HWY 42 - Waiver Request to Major Site Plan in Review Project #2017110012 #29798 Parcel #48399-004-00 Native Engineering LDC 6.11.5.C(1) - Driveway access CODE states Commercial Driveway Requirements. (1) The minimum allowed distance between a commercial driveway and the nearest intersecting roadway or driveway shall be as shown in Table 6.11-2. APPLICANT states code requires a commercial driveway to be 245 feet (<35 mph) from the nearest intersection. Our site is on the SW corner of US 301 and Hwy 42 with existing private on-site drives along the W and S property lines. This site is only 253 feet (N/S) by 270 feet (E/W), so no matter where we propose the driveways, we'd be out of compliance to access the site. In addition, we propose a gas station which requires large truck access which, in turn, requires two driveway access' to get these trucks in and out of the property in very specific areas. We request to be allowed to provide the western access to be 90 feet south of Hwy 42, and the southern access to be 100.7 feet from Hwy 301. This is to   Not available
2024-13983 16.3.New BusinessCalesa Solar Field - Standalone Waiver Request 4530 SW 66TH Court RD Ocala Project #2024010053 #31063 Parcel #3546-0016-04 Tillman & Associates Engineering LDC 6.7.8. - Protected tree replacement requirements CODE states All trees not permitted for removal must be protected and maintained. For those protected trees permitted for removal, trees shall be replaced in accordance with the minimum standards set forth below. A. Replacement is not required where the property owner retains existing trees on the site which total an average of 100 inches DBH per acre. If replacement is necessary, a minimum of 100 inches DBH per acre on the average shall be achieved. B. If the pre-development number of inches is less than 100 DBH per acre on the average, the property owner shall replace trees to equal the pre-development number of DBH inches. C. Replacement of trees less than 30 inches DBH and permitted for removal shall be as described below: (1) Existing trees measuring 10 inches DBH to 19 inches DBH shall be replaced with a ratio of one-inch replacement per two inches remov   Not available
2024-13984 16.4.New BusinessAffordable Secure Storage West SR40 - Standalone Waiver Request Project #2023080114 #31008 Parcel #2130-000-002 Local Engineering LDC 6.12.12.D - Sidewalks CODE states at the discretion of the Development Review Committee, in lieu of construction along external streets, the developer may pay a sidewalk fee to the County in an amount necessary to complete construction. This amount shall be determined by the project engineer and approved by the County with payment required prior to final plan approval. The County may use these funds toward the construction of sidewalks throughout the County based on priorities established by the Board. APPLICANT requests a waiver to pay sidewalk fee in lieu of constructing sidewalk. No sidewalk along SR40 in this area. LDC 6.8.6.D - Buffers CODE states buffers may consist of landscaping, buffer walls, fencing, berms, or combinations thereof which work cohesively to achieve the intent of buffering. APPLICANT requests a waiver to have a Vinyl Fence in lieu of Buffer Wall along north and eastern property line. Maintain visua   Not available
2024-13985 16.5.New BusinessNichols Property - Waiver Request to Major Site Plan 1328 NE 71ST LN Ocala Project #2024010043 #31049 Parcel #14733-000-00 Cardinal Construction LDC 2.21.1.A - Major Site Plan CODE states A. A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests a waiver for A-1 parcel 5.67 acres we can sheet flow to the N.W. corner then southward, without any disruption to current impervious areas on eastern half of property. Area to be added overage 6,310 square feet.   Not available
2024-13986 16.6.New BusinessEulalee Perez - Waiver Request to Major Site Plan 771 Marion Oaks Pass Ocala Project #2023110018 #30831 Parcel #8011-1402-08 Permit #2023052611 Chris Fox Aluminum LDC 2.21.1.A - Major Site Plan CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests a waiver to the major site plan to add a screen room (330 square feet). The site will be over the allowed 35 percent (3,507 square feet) per Marion County LDC.   Not available
2024-13987 16.7.New BusinessWenceslao Minami - Waiver Request to Major Site Plan 700 SE 48TH AVE Ocala Project #2024010052 #31062 Parcel #2747-002-008 Permit #2023122301 Wenceslao Minami LDC 2.21.1.A(1) - Major Site Plan CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests a waiver to the major site plan for a 36-foot by 50-foot storage shed. The overage amount is 17,531 square feet.   Not available
   7. CONCEPTUAL REVIEW ITEMS:   Not available