Please note: this meeting's Action Summary have not been finalized yet. Actions taken on legislation and their results are not available.
Meeting Name: Development Review Committee Agenda status: Final
Meeting date/time: 2/17/2025 9:00 AM Action Summary status: Draft  
Meeting location: Office of the County Engineer
Published agenda: Agenda Agenda Published Action Summary: Not available Meeting Extra1: Not available  
Agenda packet: Agenda Packet Agenda Packet
Meeting video:  
Attachments:
File #Ver.Agenda #TypeTitleActionResultVideo
     MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING.   Not available
   1. ROLL CALL   Not available
   2. PLEDGE OF ALLEGIANCE   Not available
   3. ADOPT THE FOLLOWING MINUTES:   Not available
2025-18162 13.1.MinutesFebruary 10, 2025   Not available
   4. PUBLIC COMMENT   Not available
   5. CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL   Not available
2025-18164 15.1.ConsentStone Creek by Del Webb - Arlington Amenity Center - Major Site Plan Project #2024090063 #32038 Kimley-Horn & Associates   Not available
2025-18165 15.2.ConsentYour Space Self-Storage - Major Site Plan Project #2022110040 #30776 Larson Design Group   Not available
2025-18167 15.3.ConsentBennett 6 - Final Plat Project #2023100055 #30747 Rogers Engineering Currently there are no improvements associated with this Final Plat. On 12/11/23, DRC approved waivers to the Preliminary Plat and Improvement Plan processes each subject to meeting conditions of a submittal on future lot parcels. This item was previously denied by DRC on 1/27/25 due to confirmation of title work. The title work has been reviewed by the County Land Surveyor and is now complete.   Not available
2025-18168 15.4.ConsentClark Detached Garage - Waiver Request to Major Site Plan 6230 NE 43RD Lane Rd Silver Springs Project #2025020017 #32467 Parcel #16132-015-00 Permit #2024111327 Triple Crown Homes LDC 2.21.1.A(1) - Major Site Plan CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests a waiver to the major site plan. The max amount of impervious area is 8,400. The proposed impervious area will be 10,505. The lot is approximately 302,742 which calculates to approximately 96.5 percent pervious.   Not available
   6. SCHEDULED ITEMS:   Not available
2025-18170 16.1.New BusinessGrant Property Family Division - Request for Reconsideration of Conditions to a Previously Approved Family Division Project #2007070014 #4556 Jeff and Cathy Priest This item was tabled on 2/10/25 for one week. This is a request for reconsideration and the removal of conditions and holds imposed for a Family Division that was approved by DRC on 12/7/09 and the BCC on 1/19/10. Previously Family Divisions required BCC approval. This division was from Luther and Joyce Grant to Jeff and Cathy Priest. The conditions of this division included those from a previous similar application (AR #3640) which was a division from Luther and Joyce Grant to Tara and Derek Warnock. The later division included a developer’s agreement as recorded in OR Book 5020, Pages 905-911.   Not available
2025-18171 16.2.New BusinessCalesa Township - Perlino Grove (fka: Calesa Phase 5) - Landscape Plans Only Project #2024060025 #31662 Tillman & Associates Engineering This item is for approval of the Landscape Plans associated with the Improvement Plan which was approved by the County Engineer on 1/6/25. On 8/26/24 DRC approved a waiver to LDC 6.8.2. allowing the landscape submittals to be 90 days following Improvement Plan approval. The Landscape Plans have been reviewed and approved by staff. No new comments were provided as a result of this review.   Not available
2025-18172 16.3.New BusinessWhisper Woods - Revision to AR# 28900 - Waiver Request to Improvement Plan in Review Project #2022070114 #32302 Parcel #9007-0000-12 Tillman & Associate Engineering LDC 6.13.3.D(1) - Types of Stormwater Management Facilities CODE states residential subdivisions. retention/detention areas shall have side slopes no steeper than 4:1 (horizontal: vertical) with a minimum berm width of 12 feet stabilized at six percent grade maximum around the entire perimeter of the facility. side slopes steeper than 4:1 may be allowed with additional accommodations related to public safety, maintenance, and access upon approval by the county engineer or his designee. APPLICANT requests reaffirming a previously approved waiver from AR# 28900. LDC 6.13.7.B(3) - Geotechnical Criteria CODE states infiltration/permeability tests. for retention/detention areas utilizing percolation or infiltration in the design model, there shall be a minimum of two infiltration rate tests for each retention/detention area. data used for soil permeability testing or infiltration analyses for the retention/d   Not available
2025-18173 16.4.New BusinessJumbolair Hangar Phase 2 Complex - Waiver Request to Major Site Plan in Review 8851 West Anthony Rd All Units Ocala Project #2024050073 #32136 Parcel #14105-000-00, 14601-001-00 & 14591-000-00 Rogers Engineering LDC 6.7.4.A - Shade Trees CODE states the post-development ratio of shade trees to the area of the site shall be a minimum of one shade tree per 3,000 square feet. APPLICANT requests to reconfirm original waiver of November 9, 2022 and confirms a reduction in the number of required shade trees to at least 50% of the requirement for the overall site. LDC 6.8.6.K(1) - Buffers CODE states A-Type buffer shall consist of a 30-foot wide landscape strip without a buffer wall. The buffer shall contain at least three shade trees and five accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 50 percent of the required buffer area and shall form a layered landscape screen with a minimum height of three feet achieved within one year of planting. APPLICANT requests to rec   Not available
2025-18174 16.5.New BusinessFootball Factory - Waiver Request to Major Site Plan in Review Project #2024030003 #31248 Parcel #3137-002-019 CHW LDC 6.8.6.K(2) - Buffers CODE states B-Type buffer shall consist of a 20-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 50 percent of the required buffer. APPLICANT requests waiver to install a fence in lieu of wall along SE 57th Court due to site grading (fill being placed), since it's across the roadway from the residential, and landscaping buffer plantings being provided. LDC 6.11.5.C(1) - Driveway access CODE states Commercial Driveway Requirements. (1) The minimum allowed distance between a commercial driveway and the nearest intersecting roadway or driveway shall be as shown in Table 6.11-2. APPLICANT requests waiver to Driveway spacing on SE 41 Street from SE 58th Ave and SE 57 Court. The project proposes a connection to SE 41 St. The driv   Not available
2025-18175 16.6.New BusinessFirestone Ocala Freedom - Waiver Request to Major Site Plan in Review Project #2024090064 #32039 Parcel #35699-006-06 Common Oak Engineering This waiver was denied by DRC on 2/10/25, applicant was not in attendance. The applicant requests to be reheard. LDC 6.13.6.A.(3)(c) - Stormwater quality criteria CODE states Dry retention systems that have a depth of six feet or less, measured from top of bank to pond bottom, with side slopes that are no steeper than 4:1 and sodded bottoms. APPLICANT requests waiver for the proposed dry retention pond max depth of 6 feet be allowed to be 7 feet. The soil conditions discovered in the Geo Report (7/30/24) and the updated Geo Report (1/17/25) indicate a boring of clayey fine sand 5 feet below the ground surface. Over excavation is specified to mitigate this but the extra pond volume is needed to satisfy the closed basin criteria. This waiver was denied by DRC on 2/10/25, applicant was not in attendance. The applicant requests to be reheard. LDC 6.8.6.K(2) - Buffers CODE states B-Type buffer shall consist of a 20-foot wi   Not available
2025-18176 16.7.New BusinessJordan Pagano & Dannielle Pagano - Waiver Request to Major Site Plan 5981 SE 4th Pl Ocala Project #2025020006 #32446 Parcel #31856-007-04 Permit #2025012166 Wiseman Ventures LDC 2.21.1.A(1) - Major Site Plan CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests waiver because they are adding driveway and they are over impervious. Adding french drain.   Not available
2025-18177 16.8.New BusinessRod & Cindy Chapman - Waiver Request to Major Site Plan 8273 SW 138th Street Rd Ocala Project #2025020012 #32459 Parcel #8011-1404-01 Permit #2024122564 Les Wade Pools LDC 2.21.1.A(1) - Major Site Plan CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests waiver for adding a swimming pool. Using permeable paver for pool deck but are having to add french drains for house being over impervious.   Not available
2025-18178 16.9.New BusinessCarpenter Michelle R Family Trust - Waiver Request to Major Site Plan 3377 NW 89th Ave Ocala Project #2025020016 #32466 Parcel #12669-000-06 Permit #2025011947 Hyperion Pools LDC 2.21.1.A(1) - Major Site Plan CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests waiver to the major site plan for the pool only. The site will be over the allowed 9,000 square feet.   Not available
2025-18179 16.10.New BusinessCohen In-Ground Fiberglass Swimming Pool - Waiver Request to Major Site Plan 884 SE 170th St Summerfield Project #2025020007 #32447 Parcel #44867-004-00 Permit #2025010868 Paragon Pools of NCF LDC 2.21.1.A(1) - Major Site Plan CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests waiver because the site is 20.00 acres. The owner will compensate for the increase of runoff from the future planned impervious area over 9,000 square feet. We will work with Marion County Stormwater staff on the required stormwater controls.   Not available
2025-18180 16.11.New BusinessWater Main Extension - Waiver Request to Water Main Extension 43 Pine Trace Run Ocala Project #2025010010 #32347 Parcel #9009-0078-02 Permit #2024090772 Worldwide Alliance LLC LDC 6.14.2.B(1)(a) - Water main connection CODE states New development in the Urban or Rural area shall connect to a centralized water system with available capacity if a water line is within a connection distance of 400 feet times the total number of Equivalent Residential Connections (ERCs). APPLICANT requests waiver for 380-feet connection distance; 464 extension requirements to farthest corner.   Not available
   7. CONCEPTUAL REVIEW ITEMS:   Not available
   8. DISCUSSION ITEMS:   Not available
   9. OTHER ITEMS:   Not available
   10. ADJOURN:   Not available