Skip to main content
Please note: this meeting's Action Summary have not been finalized yet. Actions taken on legislation and their results are not available.
Meeting Name: Development Review Committee Agenda status: Final
Meeting date/time: 12/15/2025 9:00 AM Action Summary status: Draft  
Meeting location: Office of the County Engineer
Published agenda: Agenda Agenda Published Action Summary: Not available Meeting Extra1: Not available  
Agenda packet: Agenda Packet Agenda Packet
Meeting video:  
Attachments:
File #Ver.Agenda #TypeTitleActionResultVideo
     MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING.   Not available
   1. ROLL CALL   Not available
   2. PLEDGE OF ALLEGIANCE   Not available
   3. ADOPT THE FOLLOWING MINUTES:   Not available
2025-21522 13.1.MinutesDecember 8, 2025   Not available
   4. PUBLIC COMMENT   Not available
   5. CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL   Not available
   6. SCHEDULED ITEMS:   Not available
2025-21527 16.1.New BusinessEl Faro Duplexes - Major Site Plan- Waiver to Major Site Plan in Review Project #2025080063 #33316 Parcel #13396-000-00 Michael W. Radcliffe Engineering, Inc. LDC 2.12.8 Current boundary and topographic survey CODE states Current boundary and topographic survey (one foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be accepted if pre-approved by the Marion County Land Surveyor. APPLICANT requests waiver to use existing survey. Nothing has changed on vacant property with no improvements. Topo is still accurate. LDC 6.13.8.B(7) Stormwater conveyance criteria CODE states (7) Sizes. Stormwater conveyance pipes and cross culverts shall be a minimum of 18 inches diameter or equivalent. Driveway culverts shall be a minimum of 15 inches diameter or equivalent for residential use and a minimum of 18 inches diameter or equivalent for commercial use. Roof dr   Not available
2025-21528 16.2.New BusinessSW 92nd Court Road Guard House - Waiver to Minor Site Plan in Review SW 92nd Court Rd Ocala Project #2025050052 #32869 Parcel #3530-0000-15 Kimley-Horn And Associates, Inc. LDC 2.20.1.A Applicability CODE states A. When any of the Minor Site Plan thresholds are exceeded, a Major Site Plan is required. B. A Minor Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements are in compliance with all of the following thresholds:(1)Collectively, all existing and proposed impervious ground coverage does not exceed 35 percent of the gross site area or 9,000 square feet, whichever is less.(2)The combined driveway trip generation is less than 50 peak hour vehicle trips.(3)The project is not in the ESOZ or FPOZ and subject to the site plan requirements of Article 5.(4)The site improvement does not increase flooding of adjacent property, or the concentration of stormwater discharge onto adjacent property. APPLICANT request - This project proposes a new turn lane th   Not available
2025-21529 16.3.New BusinessFamily Subdivision - Miller - Family Division Waiver Request 19500 NE 79th Court Rd Citra Project #000003 Parcel # 04650-010-00 Daniel & Robin Miller LDC 2.16.1.B(10) - Family Division CODE states Family Division. A parcel of record as of January 1, 1992 that is located in the Rural Land may be subdivided for use of immediate family members for their primary residences. Within the Farmland Preservation area, each new tract and the remaining parent tract must be at least three (3) acres in size. Within the Rural Land outside of the Farmland Preservation area each new tract and the remaining parent tract must be at least one acre in size. In the Urban Area, only parcels of record as of January 1, 1992 which are low density residential property exceeding two acres in size may be divided for the use of immediate family members for their primary residences up to the maximum density of one dwelling unit per gross acre. Immediate family is defined as grandparent, parent, step-parent, adopted parent, sibling, child, step-child, adopted child, or grandchild. A parcel of record shal   Not available
2025-21530 16.4.New BusinessPlat Vacation #9064-1739+05 (portion of) & 9064-1799+01 - Plat Vacation 9925SE 58th Ave Belleview Project #000019 Parcel #9064-1739+05 (portion of) & 9064-1799+01 Fred Roberts, Jr., Esq The applicant is requesting partial plat vacation to vacate one platted ORA and a portion of another. Property is to be subject to application for PUO Rezoning and subsequent replatting. Portions of property subject to vacating are to be replaced by facilities elsewhere within the replat.   Not available
2025-21531 16.5.New BusinessConservation and Future ROW Easement (Tract A sketch) - Road Closing 1891 SE 85th Street Road Ocala Project #000017 Parcel #36669-000-01 Willie B. Hayter III and Karla S. Hayter Petitioner request - Track A has remained unused since its creation when Carriage Trail was first platted. It remains in its natural state, and we hope to keep all of it that way for future generations.   Not available
2025-21532 16.6.New BusinessRiver Crest (fka River Run) - Preliminary Plat Project #2025080058 #33308 Parcel #3296-000-001 Rogers Engineering, LLC LDC 2.12.32 - Stormwater Analysis Map CODE states Provide site analysis map depicting existing and proposed drainage basins and drainage features including the existing one percent (100-year) flood plain as shown on FEMA maps with zone elevation and vertical datum noted; water line of lakes, wetlands, rivers, streams and canals; and other manmade or natural features. A note shall be provided detailing source and survey field methods used to obtain and verify data field methods of delineation of all lines shown. APPLICANT requests - The stormwater plan and permitting will be addressed during the improvement plan review. It is the intention to utilize one of the existing DRAs serving the subdivision and modify the SWFWMD permit accordingly. LDC 6.11.4 - Access management CODE states - A. All developments shall be responsible for ensuring and providing coordinated access to, from, and between the proposed development and the surrounding lands to ensur   Not available
2025-21539 16.7.New BusinessSkyworks - Major Site Plan - Waiver to Major Site Plan in Review Project #2025100049 #33518 Parcel #13326-001-00 Clymer Farner Barley, Inc. LDC 6.12.12.(D) Sidewalks CODE states D. At the discretion of the Development Review Committee, in lieu of construction along external streets, the developer may pay a sidewalk fee to the County in an amount necessary to complete construction. This amount shall be determined by the project engineer and approved by the County with payment required prior to final plan approval. The County may use these funds toward the construction of sidewalks throughout the County based on priorities established by the Board. APPLICANT request - Per 11/4/25 Initial Comments Letter, "Sidewalk is required on US 441. Staff supports the payment of a fee in lieu of construction. If approved by the DRC, the fee comes out to $12,004.50. and must be paid prior to plan approval." LDC 6.8.6 Buffers CODE states (2) B-Type buffer shall consist of a 20-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three   Not available
   7. CONCEPTUAL REVIEW ITEMS:   Not available
2025-21536 17.1.Committee ItemJumbolair Hangar Complex Phase 2 - Conceptual Review 8851 West Anthony Rd All Units Ocala Project #2024050073 #31602 Parcel #14105-000-00 Rogers Engineering, LLC   Not available
2025-21538 17.2.Committee ItemHeartland Dental - Conceptual Review Project #2025110004 #33581 Parcel #37491-003-09 & 37491-003-10 Clymer Farner Barley, Inc.   Not available
   8. DISCUSSION ITEMS:   Not available
   9. OTHER ITEMS:   Not available
   10. ADJOURN:   Not available