| | | | MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING. | | |
Not available
|
|
| | 3. | | ADOPT THE FOLLOWING MINUTES: | | |
Not available
|
|
| | 5. | | CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL | | |
Not available
|
|
2026-21936
| 1 | 5.1. | Consent | CRS Flemington N Hwy 329 & W Hwy 318 - Major Site Plan
Parcel #: 01995-001-00 #000024
NV5, Inc. | | |
Not available
|
|
2026-21938
| 1 | 6.1. | New Business | SW Hwy 484 Super Center - Major Site Plan #33171- Waiver to Major Site Plan in Review
Parcel #: 41200-056-03 #000269
Kimley-Horn and Associates
LDC 2.12.8 - Current boundary and topographic survey
CODE states Current boundary and topographic survey (one foot contour intervals extending 100 feet beyond the project boundary) based upon accepted vertical datum. Surveys will be less than 12 months old and accurately reflect current site conditions, meeting standards set forth in Ch. 5J-17 FAC. Alternate topographic data may be accepted if pre-approved by the Marion County Land Surveyor.
APPLICANT states per conversation with staff, this is a waiver request to allow for one-foot contours 25 feet beyond the project boundary instead of 100 feet beyond. | | |
Not available
|
|
2026-21939
| 1 | 6.2. | New Business | Public Storage @ SW 80th Ave Phase 2 (Liberty Village) - Major Site Plan - Waiver to Major Site Plan in Review
Parcel #: 35466-003-00 #000277
Tillman & Associates, LLC
LDC 6.7.4.A - Shade trees
CODE states the post-development ratio of shade trees to the area of the site shall be a minimum of one shade tree per 3,000 square feet.
APPLICANT requests a waiver to reduce the post-development tree ratio due to the limited available area for tree placement (0.93 acres), as well as site constraints including existing overhead power, and proposed fencing and storage buildings. Phase 1 was reduced by 50%, and Phase 2 is proposed to be reduced by 49%. A similar waiver was previously approved for the Phase 1 project (AR#24090).
LDC 6.8.6.(K)(4) - Buffers
CODE states D-Type buffer shall consist of a 15-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 25 percent of the required | | |
Not available
|
|
2026-21941
| 1 | 6.3. | New Business | 351 Marion Oaks Multifamily - Major Site Plan -000060 - Waiver to Major Site Plan in Review
Parcel #: 8004-0433-18 #000293
Linn Engineering
LDC 6.12.12.D Sidewalks
CODE states at the discretion of the Development Review Committee, in lieu of construction along external streets, the developer may pay a sidewalk fee to the County in an amount necessary to complete construction. This amount shall be determined by the project engineer and approved by the County with payment required prior to final plan approval. The County may use these funds toward the construction of sidewalks throughout the County based on priorities established by the Board.
APPLICANT requests fee in lieu of sidewalk construction. | | |
Not available
|
|
2026-21942
| 1 | 6.4. | New Business | Silver Springs State Park: Swimming Area, Kayak Launch, and Sea Hunt Area Improvements - Waiver to Major Site Plan
Parcel #: 31757-001-00 #000067
Mead & Hunt, Inc.
LDC 2.21 - Major Site Plan and LDC 6.13.5 Flood plan and protection
CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. (2) The combined driveway trip generation meets or exceeds 50 peak hour vehicle trips. (3) A 24-inch diameter pipe, its equivalent, or larger is utilized to discharge stormwater runoff from the project area.
LDC 6.13.5 Flood plan and protection
CODE states A. This section provides requirements for all land use activities, including single family residences, which materially change the location, elevation, size, capacity, or hydraulic characteristics of the existing one percent (1 | | |
Not available
|
|
2026-21943
| 1 | 6.5. | New Business | Dave & Anne Quanbeck Agricultural Lot Split - 33594
Parcel #: 05949-001-00 #33594
Clymer Farner Barley, LLC
The MSBU waiver is to be considered by the Board of County Commissioners on 2/3/26.
LDC 2.16.1.B(8) - Agricultural lot split
CODE states Agricultural lot splits outside of the Urban Growth Boundary: (a) Number of lots created under this sub-paragraph is limited to ten. (b) Each proposed lot shall be a minimum of 10 acres with at least one acre of contiguous land wholly above the one percent (100-year) flood plain or wetland. (c) Each proposed lot shall have an agricultural zoning. (d) Any lot abutting a publicly maintained and/or dedicated road that does not conform to the right-of-way width necessary to meet the minimum design standards shall dedicate necessary right-of-way or easement based upon criteria set forth in Article 6. (e) Each lot not abutting a publicly maintained and/or dedicated road shall front on a paved private road or an access easement and shall meet the minimum driveway spacing requirements established in this Code. (f) If an easement is utilized the | | |
Not available
|